摘要An off-line chelation system combined with ICP-MS technique was developed for the quantitative determination of trace elements in seawater, namely V, Co, Ni, Cu, Zn, Mo, Cd, Pb, U and rare earth elements(REEs). The system was built based on an ion chromatography equipped with MetPac((R)) CC-I chelation columns which had a strong selective chelation to these target elements within a pH range 5.2-5.6. Acidified seawater samples and NH4Ac(2 mol/L) were blended to meet suitable pH before being injected into the chelation column, thus target elements were retained while alkali and alkaline metals were excluded. Then chelated elements were eluted by HNO3 (1 mol/L) and samples were collected for ICP-MS analysis. Varying the ratio of input( gen. 200 mL) to output( gen. 5 mL), the target elements which were concentrated as 40 times as their concentrations were far beyond instrumental quantification limits. At last, a certificated seawater CASS-4 was introduced and our detected values were in good agreement with those certified values.; An off-line chelation system combined with ICP-MS technique was developed for the quantitative determination of trace elements in seawater, namely V, Co, Ni, Cu, Zn, Mo, Cd, Pb, U and rare earth elements(REEs). The system was built based on an ion chromatography equipped with MetPac((R)) CC-I chelation columns which had a strong selective chelation to these target elements within a pH range 5.2-5.6. Acidified seawater samples and NH4Ac(2 mol/L) were blended to meet suitable pH before being injected into the chelation column, thus target elements were retained while alkali and alkaline metals were excluded. Then chelated elements were eluted by HNO3 (1 mol/L) and samples were collected for ICP-MS analysis. Varying the ratio of input( gen. 200 mL) to output( gen. 5 mL), the target elements which were concentrated as 40 times as their concentrations were far beyond instrumental quantification limits. At last, a certificated seawater CASS-4 was introduced and our detected values were in good agreement with those certified values.
关键词Trace Element Seawater Off-line Chelation Ion Chromatography Icp-ms
收录类别SCI
语种英语
WOS记录号WOS:000243581800012
引用统计
被引频次:9[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.qdio.ac.cn/handle/337002/6186
专题海洋地质与环境重点实验室
作者单位1.Chinese Acad Sci, Inst Oceanol, Key Lab Marine Geol & Environm, Qingdao 266071, Peoples R China
2.Chinese Acad Sci, Grad Sch, Beijing 100039, Peoples R China
推荐引用方式
GB/T 7714
Liu Gang,Zhong Shao-Jun,Qu Chen-Li,et al. Determination of multiple trace elements in seawater using chelation ion chromatography and ICP-MS[J]. CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE,2007,28(1):53-55.
APA Liu Gang,Zhong Shao-Jun,Qu Chen-Li,Liu Fei,&Xu Li-Jun.(2007).Determination of multiple trace elements in seawater using chelation ion chromatography and ICP-MS.CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE,28(1),53-55.
MLA Liu Gang,et al."Determination of multiple trace elements in seawater using chelation ion chromatography and ICP-MS".CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE 28.1(2007):53-55.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
liu-Determination of(303KB) 限制开放--浏览
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Liu Gang]的文章
[Zhong Shao-Jun]的文章
[Qu Chen-Li]的文章
百度学术
百度学术中相似的文章
[Liu Gang]的文章
[Zhong Shao-Jun]的文章
[Qu Chen-Li]的文章
必应学术
必应学术中相似的文章
[Liu Gang]的文章
[Zhong Shao-Jun]的文章
[Qu Chen-Li]的文章
相关权益政策
暂无数据
收藏/分享
文件名: liu-Determination of multiple trace elements in seawater using chelation ion chromatography.pdf
格式: Adobe PDF
此文件暂不支持浏览
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。