Institutional Repository of Key Laboratory of Marine Environmental Corrosion and Bio-fouling, IOCAS
Selective and specific detection of sulfate-reducing bacteria using potentiometric stripping analysis | |
Wan, Yi2; Zhang, Dun1; Hou, Baorong | |
2010-09-15 | |
发表期刊 | TALANTA |
ISSN | 0039-9140 |
卷号 | 82期号:4页码:1608-1611 |
文章类型 | Article |
摘要 | A fast, sensitive and reliable potentiometric stripping analysis (PSA) is described for the selective detection of the marine pathogenic sulfate-reducing bacterium (SRB). Desulforibrio caledoiensis. The chemical and electrochemical parameters that exert influence on the deposition and stripping of lead ion, such as deposition potential, deposition time and pH value were carefully studied. The concentration of SRB was determined in acetate buffer solution (pH 5.2) under the optimized condition (deposition potential of -1.3 V. deposition time of 250 s, ionic strength of 0.2 mol L(-1) and oxidant mercury (II) concentration of 40 mg L(-1)). A linear relationship between the stripping response and the logarithm of the bacterial concentration was observed in the range of 2.3 x 10 to 2.3 x 10(7) cfu mL(-1). In addition, the potentiometric stripping technique gave a distinct response to the SRB, but had no obvious response to Escherichia coli. The measurement system has a potential for further applications and provides a facile and sample method for detection of pathogenic bacteria. (C) 2010 Elsevier B.V. All rights reserved.; A fast, sensitive and reliable potentiometric stripping analysis (PSA) is described for the selective detection of the marine pathogenic sulfate-reducing bacterium (SRB). Desulforibrio caledoiensis. The chemical and electrochemical parameters that exert influence on the deposition and stripping of lead ion, such as deposition potential, deposition time and pH value were carefully studied. The concentration of SRB was determined in acetate buffer solution (pH 5.2) under the optimized condition (deposition potential of -1.3 V. deposition time of 250 s, ionic strength of 0.2 mol L-1 and oxidant mercury (II) concentration of 40 mg L-1). A linear relationship between the stripping response and the logarithm of the bacterial concentration was observed in the range of 2.3 x 10 to 2.3 x 10(7) cfu mL(-1). In addition, the potentiometric stripping technique gave a distinct response to the SRB, but had no obvious response to Escherichia coli. The measurement system has a potential for further applications and provides a facile and sample method for detection of pathogenic bacteria. (C) 2010 Elsevier B.V. All rights reserved. |
关键词 | Potentiometric Stripping Analysis Sulfate-reducing Bacteria Pathogenic Bacteria Detection Sulfide |
学科领域 | Chemistry, Analytical |
DOI | 10.1016/j.talanta.2010.07.030 |
URL | 查看原文 |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000282480500080 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.qdio.ac.cn/handle/337002/5192 |
专题 | 海洋环境腐蚀与生物污损重点实验室 |
作者单位 | 1.Chinese Acad Sci, Inst Oceanol, Key Lab Corros Sci, Qingdao 266071, Shandong, Peoples R China 2.Chinese Acad Sci, Grad Sch, Beijing 100039, Peoples R China |
推荐引用方式 GB/T 7714 | Wan, Yi,Zhang, Dun,Hou, Baorong. Selective and specific detection of sulfate-reducing bacteria using potentiometric stripping analysis[J]. TALANTA,2010,82(4):1608-1611. |
APA | Wan, Yi,Zhang, Dun,&Hou, Baorong.(2010).Selective and specific detection of sulfate-reducing bacteria using potentiometric stripping analysis.TALANTA,82(4),1608-1611. |
MLA | Wan, Yi,et al."Selective and specific detection of sulfate-reducing bacteria using potentiometric stripping analysis".TALANTA 82.4(2010):1608-1611. |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Selective and specif(185KB) | 限制开放 | -- | 浏览 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论