IOCAS-IR  > 海洋生态与环境科学重点实验室
Fabrication of Bismuth/Multi-walled Carbon Nanotube Composite Modified Glassy Carbon Electrode for Determination of Cobalt
Wang Yuane1,2,3; Pan Dawei1; Li Xinmin1; Qin Wei1,4
2009-12-01
发表期刊CHINESE JOURNAL OF CHEMISTRY
ISSN1001-604X
卷号27期号:12页码:2385-2391
文章类型Article
摘要A bismuth/multi-walled carbon nanotube (Bi/MWNT) composite modified electrode for determination of cobalt by differential pulse adsorptive cathodic stripping voltammetry is described. The electrode is fabricated by potentiostatic pre-plating bismuth film on an MWNT modified glassy carbon (GC) electrode. The Bi/MWNT composite modified electrode exhibits enhanced sensitivity for cobalt detection as compared with the bare GC, MWNT modified and bismuth film electrodes. Numerous key experimental parameters have been examined for optimum analytical performance of the proposed electrode. With an adsorptive accumulation of the Co(II)-dimethylglyoxime complex at -0.8 V for 200 s, the reduction peak current is proportional to the concentration of cobalt in the range of 4.0x10(-11)-1.0x10(-7) mol/L with a lower detection limit of 8.1x10(-11) mol/L. The proposed method has been applied Successfully to cobalt determination in seawater and lake water samples.; A bismuth/multi-walled carbon nanotube (Bi/MWNT) composite modified electrode for determination of cobalt by differential pulse adsorptive cathodic stripping voltammetry is described. The electrode is fabricated by potentiostatic pre-plating bismuth film on an MWNT modified glassy carbon (GC) electrode. The Bi/MWNT composite modified electrode exhibits enhanced sensitivity for cobalt detection as compared with the bare GC, MWNT modified and bismuth film electrodes. Numerous key experimental parameters have been examined for optimum analytical performance of the proposed electrode. With an adsorptive accumulation of the Co(II)-dimethylglyoxime complex at -0.8 V for 200 s, the reduction peak current is proportional to the concentration of cobalt in the range of 4.0x10(-11)-1.0x10(-7) mol/L with a lower detection limit of 8.1x10(-11) mol/L. The proposed method has been applied Successfully to cobalt determination in seawater and lake water samples.
关键词Multi-walled Carbon Nanotube Bismuth Film Electrode Composite Electrode Cobalt Adsorptive Stripping Analysis Voltammetry
学科领域Chemistry, Multidisciplinary
收录类别SCI
语种英语
WOS记录号WOS:000273627600014
引用统计
被引频次:13[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.qdio.ac.cn/handle/337002/2636
专题海洋生态与环境科学重点实验室
作者单位1.Chinese Acad Sci, Yantai Inst Coastal Zone Res Sustainable Dev, Environm Chem Lab, Yantai 264003, Shandong, Peoples R China
2.Chinese Acad Sci, Inst Oceanol, Qingdao 266071, Shandong, Peoples R China
3.Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China
4.Yantai Univ, Sch Oceanol, Yantai 264005, Shandong, Peoples R China
第一作者单位中国科学院海洋研究所
推荐引用方式
GB/T 7714
Wang Yuane,Pan Dawei,Li Xinmin,et al. Fabrication of Bismuth/Multi-walled Carbon Nanotube Composite Modified Glassy Carbon Electrode for Determination of Cobalt[J]. CHINESE JOURNAL OF CHEMISTRY,2009,27(12):2385-2391.
APA Wang Yuane,Pan Dawei,Li Xinmin,&Qin Wei.(2009).Fabrication of Bismuth/Multi-walled Carbon Nanotube Composite Modified Glassy Carbon Electrode for Determination of Cobalt.CHINESE JOURNAL OF CHEMISTRY,27(12),2385-2391.
MLA Wang Yuane,et al."Fabrication of Bismuth/Multi-walled Carbon Nanotube Composite Modified Glassy Carbon Electrode for Determination of Cobalt".CHINESE JOURNAL OF CHEMISTRY 27.12(2009):2385-2391.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
wang-Fabrication of (122KB) 限制开放--浏览
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Wang Yuane]的文章
[Pan Dawei]的文章
[Li Xinmin]的文章
百度学术
百度学术中相似的文章
[Wang Yuane]的文章
[Pan Dawei]的文章
[Li Xinmin]的文章
必应学术
必应学术中相似的文章
[Wang Yuane]的文章
[Pan Dawei]的文章
[Li Xinmin]的文章
相关权益政策
暂无数据
收藏/分享
文件名: wang-Fabrication of Bismuth.pdf
格式: Adobe PDF
此文件暂不支持浏览
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。