Institutional Repository of Key Laboratory of Marine Ecology & Environmental Sciences, CAS
Fabrication of Bismuth/Multi-walled Carbon Nanotube Composite Modified Glassy Carbon Electrode for Determination of Cobalt | |
Wang Yuane1,2,3; Pan Dawei1; Li Xinmin1; Qin Wei1,4 | |
2009-12-01 | |
发表期刊 | CHINESE JOURNAL OF CHEMISTRY |
ISSN | 1001-604X |
卷号 | 27期号:12页码:2385-2391 |
文章类型 | Article |
摘要 | A bismuth/multi-walled carbon nanotube (Bi/MWNT) composite modified electrode for determination of cobalt by differential pulse adsorptive cathodic stripping voltammetry is described. The electrode is fabricated by potentiostatic pre-plating bismuth film on an MWNT modified glassy carbon (GC) electrode. The Bi/MWNT composite modified electrode exhibits enhanced sensitivity for cobalt detection as compared with the bare GC, MWNT modified and bismuth film electrodes. Numerous key experimental parameters have been examined for optimum analytical performance of the proposed electrode. With an adsorptive accumulation of the Co(II)-dimethylglyoxime complex at -0.8 V for 200 s, the reduction peak current is proportional to the concentration of cobalt in the range of 4.0x10(-11)-1.0x10(-7) mol/L with a lower detection limit of 8.1x10(-11) mol/L. The proposed method has been applied Successfully to cobalt determination in seawater and lake water samples.; A bismuth/multi-walled carbon nanotube (Bi/MWNT) composite modified electrode for determination of cobalt by differential pulse adsorptive cathodic stripping voltammetry is described. The electrode is fabricated by potentiostatic pre-plating bismuth film on an MWNT modified glassy carbon (GC) electrode. The Bi/MWNT composite modified electrode exhibits enhanced sensitivity for cobalt detection as compared with the bare GC, MWNT modified and bismuth film electrodes. Numerous key experimental parameters have been examined for optimum analytical performance of the proposed electrode. With an adsorptive accumulation of the Co(II)-dimethylglyoxime complex at -0.8 V for 200 s, the reduction peak current is proportional to the concentration of cobalt in the range of 4.0x10(-11)-1.0x10(-7) mol/L with a lower detection limit of 8.1x10(-11) mol/L. The proposed method has been applied Successfully to cobalt determination in seawater and lake water samples. |
关键词 | Multi-walled Carbon Nanotube Bismuth Film Electrode Composite Electrode Cobalt Adsorptive Stripping Analysis Voltammetry |
学科领域 | Chemistry, Multidisciplinary |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000273627600014 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.qdio.ac.cn/handle/337002/2636 |
专题 | 海洋生态与环境科学重点实验室 |
作者单位 | 1.Chinese Acad Sci, Yantai Inst Coastal Zone Res Sustainable Dev, Environm Chem Lab, Yantai 264003, Shandong, Peoples R China 2.Chinese Acad Sci, Inst Oceanol, Qingdao 266071, Shandong, Peoples R China 3.Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China 4.Yantai Univ, Sch Oceanol, Yantai 264005, Shandong, Peoples R China |
第一作者单位 | 中国科学院海洋研究所 |
推荐引用方式 GB/T 7714 | Wang Yuane,Pan Dawei,Li Xinmin,et al. Fabrication of Bismuth/Multi-walled Carbon Nanotube Composite Modified Glassy Carbon Electrode for Determination of Cobalt[J]. CHINESE JOURNAL OF CHEMISTRY,2009,27(12):2385-2391. |
APA | Wang Yuane,Pan Dawei,Li Xinmin,&Qin Wei.(2009).Fabrication of Bismuth/Multi-walled Carbon Nanotube Composite Modified Glassy Carbon Electrode for Determination of Cobalt.CHINESE JOURNAL OF CHEMISTRY,27(12),2385-2391. |
MLA | Wang Yuane,et al."Fabrication of Bismuth/Multi-walled Carbon Nanotube Composite Modified Glassy Carbon Electrode for Determination of Cobalt".CHINESE JOURNAL OF CHEMISTRY 27.12(2009):2385-2391. |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
wang-Fabrication of (122KB) | 限制开放 | -- | 浏览 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论