Spatial resolution comparison of AC-SECM with SECM and their characterization of self-healing performance of hexamethylene diisocyanate trimer microcapsule coatings
Wang, Wei1,2; Xu, Likun1; Sun, Huyuan2; Li, Xiangbo1; Zhao, Shouhuan3; Zhang, Weining4
2015-03-14
发表期刊JOURNAL OF MATERIALS CHEMISTRY A
卷号3期号:10页码:5599-5607
文章类型Article
摘要Hexamethylene diisocyanate trimer (HDIt) microcapsules were synthesized by in situ polymerization and were characterized via field emission-scanning electron microscopy, fluorescence microscopy, and Fourier transform infrared spectroscopy. We added HDIt microcapsules into epoxy resin coatings as functional additives and then assessed the resulting self-healing performance of the epoxy resin coatings using a scratched crevice on a 5083 aluminum surface as a test scenario. The protective coating with the HDIt microcapsules had robust self-healing after the samples were immersed in a solution of 0.6 M NaCl for 48 h. Healing efficiencies of epoxy resin coatings as high as 45.3 +/- 2.9%, characterized by a fracture test, were achieved for 16 wt% HDIt microcapsules. The self-healing ability was further shown by using scanning electrochemical microscopy (SECM) and alternating current scanning electrochemical microscopy (AC-SECM). We found that AC-SECM offered additional local electrochemical topographies of the self-healing surface at different AC frequencies. Comparing the two topographical tests obtained from both SECM and AC-SECM revealed that AC-SECM achieved better spatial resolution and was less influenced by the scanning step size and the cleanliness of the tip surface.
DOI10.1039/c5ta00529a
收录类别SCI
语种英语
WOS记录号WOS:000350682100046
引用统计
被引频次:32[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.qdio.ac.cn/handle/337002/25412
专题海洋环境腐蚀与生物污损重点实验室
作者单位1.Luoyang Ship Mat Res Inst, State Key Lab Marine Corros & Protect, Qingdao 266101, Peoples R China
2.Chinese Acad Sci, Inst Oceanol, Key Lab Marine Environm Corros & Biofouling, Qingdao 266071, Peoples R China
3.Shanghai Ocean Univ, Food Sci & Technol Coll, Shanghai 201306, Peoples R China
4.Beijing Yinglong Technol Co Ltd, Beijing 100073, Peoples R China
第一作者单位中国科学院海洋研究所
推荐引用方式
GB/T 7714
Wang, Wei,Xu, Likun,Sun, Huyuan,et al. Spatial resolution comparison of AC-SECM with SECM and their characterization of self-healing performance of hexamethylene diisocyanate trimer microcapsule coatings[J]. JOURNAL OF MATERIALS CHEMISTRY A,2015,3(10):5599-5607.
APA Wang, Wei,Xu, Likun,Sun, Huyuan,Li, Xiangbo,Zhao, Shouhuan,&Zhang, Weining.(2015).Spatial resolution comparison of AC-SECM with SECM and their characterization of self-healing performance of hexamethylene diisocyanate trimer microcapsule coatings.JOURNAL OF MATERIALS CHEMISTRY A,3(10),5599-5607.
MLA Wang, Wei,et al."Spatial resolution comparison of AC-SECM with SECM and their characterization of self-healing performance of hexamethylene diisocyanate trimer microcapsule coatings".JOURNAL OF MATERIALS CHEMISTRY A 3.10(2015):5599-5607.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Spatial resolution c(2193KB)期刊论文出版稿限制开放ODC PDDL浏览
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Wang, Wei]的文章
[Xu, Likun]的文章
[Sun, Huyuan]的文章
百度学术
百度学术中相似的文章
[Wang, Wei]的文章
[Xu, Likun]的文章
[Sun, Huyuan]的文章
必应学术
必应学术中相似的文章
[Wang, Wei]的文章
[Xu, Likun]的文章
[Sun, Huyuan]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Spatial resolution comparison of AC-SECM with SECM and their characterization of self-healing performance of hexamethylene diisocyanate trimer microcapsule coatings.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。