Institutional Repository of Key Laboratory of Ocean Circulation and Wave Studies, Institute of Oceanology, Chinese Academy of Sciences
CARBON NANOTUBES/IONOPHORE MODIFIED ELECTRODE FOR ANODIC STRIPPING DETERMINATION OF LEAD | |
Lou, Tingting1,2,3,4; Pan, Dawei1,2,5; Wang, Yuane1,2,3,4; Jiang, Lin1,2,3,4; Qin, Wei1,2 | |
2011 | |
发表期刊 | ANALYTICAL LETTERS
![]() |
ISSN | 0003-2719 |
卷号 | 44期号:10页码:1746-1757 |
文章类型 | Article |
摘要 | Bifunctional combination of carbon nanotubes and ionophore is introduced for anodic stripping analysis of lead (Pb(2+)). Carbon nanotubes are employed to improve the detection sensitivity due to their excellent electrical conductivity and strong adsorption ability. An ionophore is utilized for its excellent selectivity toward Pb(2+). The proposed carbon nanotubeslionophore modified electrode shows improved sensitivity and selectivity for Pb(2+). Low detection limit (1 nM), wide linear range (5 nM-8 mu M) and excellent selectivity over other metal ions (Cd(2+), Cu(2+), and Hg(2+)) was obtained. The practical application has been carried out for determination of Pb(2+) in real water samples.; Bifunctional combination of carbon nanotubes and ionophore is introduced for anodic stripping analysis of lead (Pb(2+)). Carbon nanotubes are employed to improve the detection sensitivity due to their excellent electrical conductivity and strong adsorption ability. An ionophore is utilized for its excellent selectivity toward Pb(2+). The proposed carbon nanotubeslionophore modified electrode shows improved sensitivity and selectivity for Pb(2+). Low detection limit (1 nM), wide linear range (5 nM-8 mu M) and excellent selectivity over other metal ions (Cd(2+), Cu(2+), and Hg(2+)) was obtained. The practical application has been carried out for determination of Pb(2+) in real water samples. |
关键词 | Anodic Stripping Analysis Carbon Nanotubes Ionophore Lead |
学科领域 | Chemistry |
DOI | 10.1080/00032719.2010.526272 |
URL | 查看原文 |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000294602100002 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.qdio.ac.cn/handle/337002/11563 |
专题 | 海洋环流与波动重点实验室 |
作者单位 | 1.Chinese Acad Sci, Yantai Inst Coastal Zone Res, Shandong Prov Key Lab Coastal Zone Environm Proc, Yantai 264003, Peoples R China 2.Chinese Acad Sci, Yantai Inst Coastal Zone Res, CAS, Yantai 264003, Peoples R China 3.Chinese Acad Sci, Inst Oceanol, Qingdao, Peoples R China 4.Chinese Acad Sci, Grad Univ, Beijing, Peoples R China 5.Hunan Univ, State Key Lab Chemo Biosensing & Chemometr, Changsha 410082, Hunan, Peoples R China |
推荐引用方式 GB/T 7714 | Lou, Tingting,Pan, Dawei,Wang, Yuane,et al. CARBON NANOTUBES/IONOPHORE MODIFIED ELECTRODE FOR ANODIC STRIPPING DETERMINATION OF LEAD[J]. ANALYTICAL LETTERS,2011,44(10):1746-1757. |
APA | Lou, Tingting,Pan, Dawei,Wang, Yuane,Jiang, Lin,&Qin, Wei.(2011).CARBON NANOTUBES/IONOPHORE MODIFIED ELECTRODE FOR ANODIC STRIPPING DETERMINATION OF LEAD.ANALYTICAL LETTERS,44(10),1746-1757. |
MLA | Lou, Tingting,et al."CARBON NANOTUBES/IONOPHORE MODIFIED ELECTRODE FOR ANODIC STRIPPING DETERMINATION OF LEAD".ANALYTICAL LETTERS 44.10(2011):1746-1757. |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
CARBON NANOTUBES ION(322KB) | 限制开放 | -- | 浏览 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论